E-Mail: firstfurnace@gmail.com
whatsapp:+8618037961302
Adress: Luoxin Industrial Park, Luoyang, HenanLarge AC Motors Terminal Rings
Medium-frequency welding of mo
Medium-Frequency Brazing Equip
Integral Brazing Process for t
Online Heating Equipment for T
Online Heating Equipment for A
Aluminum ingot heating equipme
Welding Equipment for Traction
Fully Digital Medium Frequency
Motor rotor end ring brazing e
Brazing equipment for hydro ge
Generator rod induction brazin
Hydropower generator stator ba
Large diameter steel pipe quen
Piston rod quenching and tempe
Grinding rod quenching and tem
induction heating machine 
The purpose of the billet intermediate frequency induction heating furnace : used to heat carbon steel, alloy steel, ball bearing steel, including ferritic steel and austenitic steel, to the maximum extrusion temperature of 1250T . Billet "plus hot" furnace heated to 1250T after the punch a hole shall be due to a decrease in the temperature of the billet , "then the heating" furnace, and then extruded.
The intermediate frequency induction heating furnace can process 4 kinds of billets with different diameters. Changing from one diameter billet to another diameter billet requires some adjustments to the furnace and replacement of the inductor.
The structure of the intermediate frequency induction heating furnace: The induction heating furnace is vertical and uses hydraulic transmission, which is convenient for automatic control.
The coil of the inductor is wound with a special-shaped pure copper tube, arranged in a single layer, cooled by water, with a magnetic conductor, and an open tube made of high temperature resistant material in the coil, and there is a protection between the coil and the heat resistant tube cylinder.
"Plus hot" and the furnace "re Technical Data heating" of the furnace are shown in Table 12-8 .
Table 12-8 Technical parameters of heating furnace and reheating furnace
|
Serial number |
name |
"Plus hot" furnace |
" Reheat" furnace |
|
|||
|
1 |
Rated power of adjustable transformer /kV - A |
850 |
700 |
|
|||
|
2 |
Transformer power supply voltage /V |
6000 |
6000 |
|
|||
|
3 |
Transformer secondary voltage/level |
10 |
10 |
|
|||
|
4 |
Sensor power /kW |
750 |
600 |
|
|||
|
|
|
|
|
|
|||
|
(Continued) |
|||||||
|
Serial number |
name |
"Plus hot" furnace |
" Reheat" furnace |
||||
|
5 |
Blank material |
Magnetic and non-magnetic steel |
Magnetic and non-magnetic steel |
||||
|
6 |
Sensor connection |
Simplex |
Simplex |
||||
|
7 |
Maximum heating temperature /Y |
1250 |
1250 |
||||
|
8 |
Sensor voltage /V |
600 |
600 |
||||
|
9 |
Pressure of cooling water /Pa |
3 X10 5 |
3 X10 5 |
||||
|
10 |
Cooling water consumption/ (m'/h) |
12. |
12 |
||||
The dimensions of the billet and the inductor of the heating furnace are shown in Table 12-9 .
Table 12-9 Relevant dimensions of the sensor (unit: mm)