Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • Gear hardening machine

    Large diameter steel pipe quen

    Piston rod quenching and tempe

    Hand-held induction heater

    Grinding rod quenching and tem

    Induction forging machine

    induction heating machine 

    Induction heater

    High frequency induction heate

    Super audio induction heating

    Super audio induction heating

    Guideway quenching integrated

    Quenching equipment for machin

    Round steel end heating furnac

    Steel pipe heat treatment prod

    Square steel quenching and tem

    Sucker rod quenching and tempe

    Thickened petroleum steel pipe

    Round steel quenching and temp

    Steel pipe quenching and tempe

    Steel plate quenching and temp

    Induction Hardening Machine&nb

    Flywheel ring gear high freque

    Oil drill pipe quenching and t

    Iron induction furnace

    Aluminum melting furnace

    Copper melting furnace

    Small steel melting furnace

    Electric furnace technical parameters(²ÎÊý£©
        Induction melting furnace can not start analysis
    Symptom: The device cannot be started. Only the DC current meter has an indication when starting. There is no indication for the DC voltage and the intermediate frequency voltmeter.
    Fault analysis and processing are as follows:
        1. The inverter trigger pulse has a missing pulse phenomenon. Check the inverter pulse with an oscilloscope (preferably on the G-K of the thyristor). If there is a missing pulse, check if the connection has poor contact or open circuit. Is there any pulse output at the front stage?
        2. Inverter thyristor breakdown. Use a multimeter to measure the resistance between A and K. In the absence of cooling water, the value of A-K should be greater than 10K, and the resistance is 0. If there are two damages during the measurement, remove one of the connected copper bars and judge whether one or two are damaged. Replace the thyristor and check the cause of the thyristor damage.
    3. Capacitor breakdown. Use the ¡Á IK block of the pointer multimeter to measure the capacitance of each column to the common terminal. If there is no indication that the column is broken, remove the damaged capacitor pole.
    4. The load has a short circuit and grounding. The resistance of the coil to ground (without cooling water) can be measured with a 1000V megger (shake table), which should be greater than 1M¦¸, otherwise the short-circuit point and grounding point should be excluded.
    5. The IF signal sampling loop has an open or short circuit. Use an oscilloscope to observe the waveform of each signal sampling point, or use a multimeter to measure the resistance value of each signal sampling loop to find the open or short point. Focus on the intermediate frequency feedback transformer, whether the primary side is open (caused by the snorkeling sensation).