Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • 0.5T intermediate frequency me

    Medium Frequency Induction Mel

    250kg induction melting f

    500kg medium frequency in

    5T Medium Frequency Induction

     5T Induction Meltin

     500kg induction mel

    induction melting furnace

    3T medium frequency induction

    2T frequency induction me

    1T Medium Frequency Induction

    Bar heating furnace

    300KG electromagnetic melting

    250 KG electromagnet

    200 KG electromagnet

    silver melting furnace

    Brass melting Furnace

    atomization milling equipment

    Platinum melting furnace

    Selection of common spare part

    Medium frequency copper meltin

    scrap copper melting furnace

    800kg electromagnetic

    600KG electromagnetic copper m

    500KG electromagnetic

    400KG electromagnetic copper m

    350KG electromagnetic copper m

    300KG electromagnetic copper m

    Electric furnace principle
        Thyristor medium frequency electric furnace shock treatment method

    Intermediate frequency furnace maintenance: thyristor medium frequency electric furnace shock treatment method 1: The intermediate frequency furnace can not be started, only the DC current meter has indication when starting, and the DC voltage and intermediate frequency voltmeter have no indication.

    Inverter trigger pulse phenomenon, use the oscilloscope to check the inverter pulse (check on the thyristor AK), if there is a lack of pulse phenomenon, check whether the connection is not well contacted or open circuit, whether there is pulse output in the front stage.


    Inverter thyristor breakdown and replacement of thyristor.
    The capacitor is broken down and the damaged capacitor pole is removed.
    The load has a short circuit, grounding phenomenon, and the short circuit point and grounding point are eliminated.
    The IF signal sampling loop has an open or short circuit phenomenon. Use an oscilloscope to observe the waveform of each signal sampling point and find the open or short circuit point.
    Medium frequency furnace maintenance: thyristor medium frequency electric furnace shock treatment method 2: When the heavy load cold furnace starts, the electrical parameters and sounds are normal but the power is not up to overcurrent protection.
    Analysis and processing:
    The inverse transform flow angle is too small. Use an oscilloscope to view the commutation angle of the inverter thyristor, and adjust the commutation angle to an appropriate value;
    The insulation resistance of the furnace body is low or short-circuited, and the resistance value of the furnace body is detected by a megger to eliminate the short-circuit point of the furnace body;
    The resistance of the furnace steel relative to the induction coil is low, and the resistance of the furnace relative to the induction coil is detected by a megohmmeter; if the resistance is low, the furnace is rebuilt.
    The furnace switch has a grounding phenomenon or the switch contacts have poor contact, and the furnace switch or contact is replaced.
    Medium frequency furnace maintenance: thyristor medium frequency electric furnace shock treatment method 3: starting difficulty, the maximum DC voltage can only rise to 1400v after starting, and the reactor vibration is large, the sound is dull.
    Rectifier thyristor open circuit, breakdown, soft breakdown or electrical parameter performance degradation, use an oscilloscope to observe the voltage drop waveform of each rectifier thyristor, find the damaged thyristor and replace it.
    A set of rectification trigger pulses is missing. Each oscilloscope is used to check each trigger pulse. When a loop without a pulse is detected, the fault location is determined by the reverse push method, and the damaged device is replaced.

    Copyright© 2007-2013 songdao Electric furnace manufacturing Co,.Ltd All Rights Reserved
    Tel:18037961302 Sales hot line ( 24 hours service): 18037961302
    E-Mail:firstfurnace@gmail.com
    Adress: Luoxin Industrial Park, Luoyang, Henan