Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • 0.25T Intermediate Frequency F

    0.5T Intermediate Frequency Fu

    Medium Frequency Furnace

    2T Induction Melting Furnace

    1T Induction Melting Furnace

    500kg Induction Melting Furnac

    250kg Induction Melting Furnac

    Induction Melting Furnace

    3 T Induction Melting Furnace

    5T Induction Melting Furnace

    1T One Belt Two Intermediate F

    5T One Belt Two Intermediate F

    3T One Belt Two Intermediate F

    2T One Belt Two Intermediate F

    5T Parallel Intermediate Frequ

    5T Intermediate Frequency Furn

    5T Series Intermediate Frequen

    3T Series Intermediate Frequen

    2T Series Intermediate Frequen

    1T Series Intermediate Frequen

    0.5T Series Intermediate Frequ

    0.25T Series Intermediate Freq

    1T Parallel Intermediate Frequ

    2T Parallel Intermediate Frequ

    0.5T Parallel Intermediate Fre

    0.25T Parallel Intermediate Fr

    Parallel Intermediate Frequenc

    3T Intermediate Frequency Furn

    Electric furnace repair
        

    Medium frequency electric furnace water stop emergency plan

    1. Purpose: To strengthen on-site technical management, standardize the operation of induction melting furnace smelting, and prevent safety accidents.


    2. Phenomenon: The induction melting  furnace suddenly stops water, and the melting water pressure gauge of the melting furnace sends out a signal to automatically cut off the power supply of the intermediate frequency furnace to issue an alarm signal. Subsequently, the induction copper tube is baked by high-temperature molten iron to form a buzzing sound that occurs when the temperature of the cooling water rises sharply to generate steam.




    3. Reason: Sudden power outage or cooling water pump burned out.

    4. Hazard: Water stoppage can cause the insulating paint on the induction copper tube to burn or deform, or the sharply generated high-pressure steam account can break the cooling water hose.

    5. Treatment: The water pump burns off the total inlet valve of the cooling water system, opens the spare water pump or the emergency cooling water tank valve, quickly starts the unit when the power is cut off or opens the emergency cooling water tank valve to ensure the cooling water supply of the induction coil. The water supply pressure is 01. 0.16Mpa, and ensure that the cooling water supplies water to the induction coil for 2 to 4 hours.

    6. Prevention: Check the temperature of the cooling water pump and do a good job of communicating with the power supply system.

    7. Rescue measures: Immediately close the cooling water pump valve that has been burned out or power outage, and open the emergency water tank valve or generator set.

    8. Emergency steps:

    1 Turn off the power of the burned or de-cooled cooling water pump motor.

    2 Close the burned or de-energized cooling water pump valve.

    3 Open the emergency tank valve or backup generator set connected to the intermediate frequency furnace.

    4 The shift supervisor informed the dispatcher in time, the workshop director, to find out the reason, and resume the normal water supply, restart the intermediate frequency furnace according to the operating procedures.