Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • 0.25T Intermediate Frequency F

    0.5T Intermediate Frequency Fu

    Medium Frequency Furnace

    2T Induction Melting Furnace

    1T Induction Melting Furnace

    500kg Induction Melting Furnac

    250kg Induction Melting Furnac

    Induction Melting Furnace

    3 T Induction Melting Furnace

    5T Induction Melting Furnace

    1T One Belt Two Intermediate F

    5T One Belt Two Intermediate F

    3T One Belt Two Intermediate F

    2T One Belt Two Intermediate F

    5T Parallel Intermediate Frequ

    5T Intermediate Frequency Furn

    5T Series Intermediate Frequen

    3T Series Intermediate Frequen

    2T Series Intermediate Frequen

    1T Series Intermediate Frequen

    0.5T Series Intermediate Frequ

    0.25T Series Intermediate Freq

    1T Parallel Intermediate Frequ

    2T Parallel Intermediate Frequ

    0.5T Parallel Intermediate Fre

    0.25T Parallel Intermediate Fr

    Parallel Intermediate Frequenc

    3T Intermediate Frequency Furn

    Electric furnace industry news
        

    What should I do if the MF melting furnace current is large ?

    Since the new furnace, the current will not go up. Later, two capacitors (serial-parallel circuit) were added. The current is too large, the voltage is not going up, and there is time to trip. What is the reason? Answer: Then take the two capacitors off and see what the current voltage is. (There is no comparison of the current load.) I used to look at the data. I asked: The furnace is small. Answer: The furnace is small and the current will of course be reduced. Small. It is not a fault. It will be big when you adjust the board. Or if you use a few furnaces, the current will be higher. The capacitor will increase the vibration, and the current will trip. Now it has more than ten furnaces. Answer: The new furnace induction coil has leakage, which is easy to cause low voltage. Just do it. What kind of control board is your furnace? I don't know how long you have been repairing? Have time to exchange. Supplement: Capacity And the inductance of the induction coil needs to be within a certain range. Asked: How to determine this range! I am this 10T furnace answer: related to the operating frequency of the intermediate frequency melting furnace