Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • Gear hardening machine

    Large diameter steel pipe quen

    Piston rod quenching and tempe

    Hand-held induction heater

    Grinding rod quenching and tem

    Induction forging machine

    induction heating machine 

    Induction heater

    High frequency induction heate

    Super audio induction heating

    Super audio induction heating

    Guideway quenching integrated

    Quenching equipment for machin

    Round steel end heating furnac

    Steel pipe heat treatment prod

    Square steel quenching and tem

    Sucker rod quenching and tempe

    Thickened petroleum steel pipe

    Round steel quenching and temp

    Steel pipe quenching and tempe

    Steel plate quenching and temp

    Induction Hardening Machine&nb

    Flywheel ring gear high freque

    Oil drill pipe quenching and t

    Iron induction furnace

    Aluminum melting furnace

    Copper melting furnace

    Small steel melting furnace

    Electric furnace repair£¨Î¬ÐÞ£©
        

    Over-current action after the induction melting furnace presses the start button

    First, the phenomenon of failure 

    After pressing the IF start button, the overcurrent protection action causes the rectifier to be pulled into the inverter state.

    Second, failure analysis and processing 

    For the newly installed intermediate frequency power supply, check whether the voltage polarity is correct, whether the polarity of the inverter pulse is correct, and whether the lead angle is too small. Since there is no polarity problem for the already operated intermediate frequency power supply, it can be detected from the following aspects.

    (1) Use a multimeter to measure the damage of the thyristor and the fast fuse. If it is damaged, replace the thyristor fast fuse melt.

    (2) Check if the load circuit is short-circuited and the load is too heavy.

    (3) Use an oscilloscope to check if the lead angle is too small, if the inverter pulse has interference, and if the thyristor characteristics deteriorate.

    (4) Check if the overcurrent protection setting value has changed. If it changes, it should be re-tuned.

    (5) Check if the current feedback is too large. If the feedback amount is too large, the oscillation will stop. If it is normal, check if the voltage feedback signal is off.

    (6) Check if the DC output voltage of the rectifier circuit is too low and whether the insulation of the IF power load circuit is reduced.


    Copyright© 2007-2013 songdao Electric furnace manufacturing Co,.Ltd All Rights Reserved