Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • Large AC Motors Terminal Rings

    Electric Motor Rotor Bars and

    Medium-frequency welding of mo

    Medium-Frequency Brazing Equip

    Integral Brazing Process for t

    Online Heating Equipment for T

    Online Heating Equipment for A

    Aluminum ingot heating equipme

    Welding Equipment for Traction

    Fully Digital Medium Frequency

    Motor rotor end ring brazing e

    Motor Rotor Guide Bar Welding

    Brazing equipment for hydro ge

    Generator rod induction brazin

    Hydropower generator stator ba

    Gear hardening machine

    Large diameter steel pipe quen

    Piston rod quenching and tempe

    Hand-held induction heater

    Grinding rod quenching and tem

    Induction forging machine

    induction heating machine 

    Induction heater

    High frequency induction heate

    Super audio induction heating

    Super audio induction heating

    Guideway quenching integrated

    Quenching equipment for machin

    Electric furnace technical parameters(参数)
        Safety features of the core components of induction melting furnace
    The thyristor is the core of the IF power supply, and its accurate use is critical to the operation of the facility. It is normal for one facility to damage three or five thyristors a year. If the silicon is often burned and the electric furnace is shut down, affecting the production, it will cause vigilance. The operating current of the thyristor ranges from a few hundred amps to several thousand amps, and the voltage is usually one to two kilovolts. Good main control board protection and good water cooling conditions are necessary.
    Overload characteristics of thyristors: The damage of thyristors is called breakdown. Under normal water-cooling conditions, the current overload capacity can reach more than 110%; no voltage overload capacity, that is to say, silicon is definitely damaged under overpressure conditions. Taking into account the surge voltage, manufacturers often choose silicon components at 3-4 times the operating voltage when manufacturing facilities.
    The exact installation pressure of the thyristor: 150-200KG/cm2. When the facility is shipped from the factory, it is usually press-fitted with a hydraulic press. Manually using ordinary wrenches can not reach this value with maximum force. Therefore, when manually pressing, there is no need to worry that silicon will be crushed; if it is loosened, it will burn silicon due to poor heat dissipation.
    SCR radiator structure: water-cooled cavity + multi-copper column support. If the circulating water is too hard, it will foul inside the water chamber, causing poor heat dissipation; if the water chamber enters the leaves and other debris, it will also cause poor water flow.